You have no items in your cart.
20KW-250KW Hybrid Solar Inverter
20KW-250KW Hybrid Solar Inverter
Features:
- Pure sine wave output
- With MPPT solar charge controller 30A-100A (Optional) With UPS automatic switching function, grid power charging function, AVR voltage stabilization function
- It has perfect protection functions such as overload, high voltage, low voltage, short circuit, etc
- DSP Intelligent Chip Control, Excellent Performance
- Strong inverting capability, one-time soft start, triple output peak power, with all inductive loads
- Full personalized LCD display, it can display various data information of inverter, solar charge controller
- Grid power priority, energy saving mode and solar energy priority can be set freely to meet different occasions
- Battery type, charging voltage grid power charging current (0- 35A) can be set freely to meet the charging management of different types of batteries
4.510,00 € Excl. VAT
Availability: In Stock
20KW-250KW Hybrid Solar Inverter
Features:
- Pure sine wave output
- With MPPT solar charge controller 30A-100A (Optional) With UPS automatic switching function, grid power charging function, AVR voltage stabilization function
- It has perfect protection functions such as overload, high voltage, low voltage, short circuit, etc
- DSP Intelligent Chip Control, Excellent Performance
- Strong inverting capability, one-time soft start, triple output peak power, with all inductive loads
- Full personalized LCD display, it can display various data information of inverter, solar charge controller
- Grid power priority, energy saving mode and solar energy priority can be set freely to meet different occasions
- Battery type, charging voltage grid power charging current (0- 35A) can be set freely to meet the charging management of different types of batteries
Specification:
Â
MODEL | T5K | T6K | T8K | T10K | T20K | T30K | T50K | T60K | T100K | |
Power | 5KW | 6KW | 8KW | 10KW | 20KW | 30KW | 50KW | 60KW | 100KW | |
Power Factor | 0.8 | |||||||||
Â
 Input |
Phase | 3 phase 4 wire and ground | ||||||||
Voltage Range | 380V± 20%(3 phase), phase voltage 220V | |||||||||
Frequency Range | Â
45 – 65Hz |
|||||||||
Rectifier | 3 phase 6 pulses, 12 pulses is optional | |||||||||
Â
       Output |
Phase | 3 phase 4 wire and ground | ||||||||
Wave form | Pure sine wave | |||||||||
Crest Factor | 3: 01 | |||||||||
Rated voltage | 380/400/415V optional+ -1% for static load, 5% forfluctuant load | |||||||||
Phase voltage setting | Â
200 – 244VAC, pls confirm when order |
|||||||||
Transient response | Â
+/-5%, 10ms |
|||||||||
Frequency | 50 / 60 Hz + / – 0.05% | |||||||||
Total-harmonic distortion | Â
< 3% linear load, < 5%( nonlinear load) |
|||||||||
Short circuit current | Â
Short current for 0.1s (200% current) |
|||||||||
Overload capacity | Overload 125% for 10 Mins, 125%-150% for 1min. automatically resume when load become normal | |||||||||
Â
 Battery |
Battery | Maintenance free lead-acid cell | ||||||||
DC Voltage | 48v or 96V(1-15KW) | 384V | ||||||||
Max Charge Current | Â
6-30A adjustable |
|||||||||
Â
  Bypass |
Type | Static state + manual maintenance bypass | ||||||||
Input Phase | 3 phase 4 wire and ground | |||||||||
Input voltage range | Â
15% – 25% (the front control panel selectable) |
|||||||||
Â
Transfer time |
Inverter / bypass transfer switch time(Overload): 0ms inverter / bypass transfer switch time (fault inverter) 1ms |
Â
Efficien cy | Whole unit | > 85% | ||||||||
Inverter | 91 | 91 | 92 | 92 | 93 | 93 | 95 | 95 | 95 | |
Â
Remote signaling |
Dry contact (battery low, battery discharging, bypass/ fault); output 12Vdc/80mA, Optional parts | |||||||||
Communication interface | RS232 ( SNMP, modem optional ) | |||||||||
Running temperature | 0-40 degree Celsius | |||||||||
Relative Humidity | Less than 95% (without condensing) | |||||||||
Noise at 1 M | less than 60 dB | |||||||||
Degree of protection | IP20 | |||||||||
Applicable Standards | EN50091-1-EMC EN50091-2liv. A | |||||||||
Product size(mm) | 700*364*969 | 700*364*969 | 785*580*1200 | 1200*900*1820 | ||||||
product weight(Kg) | 80 | 82 | 85 | 108 | 125 | 190 | 380 | 690 | 800 | |
Â
Package size(mm) |
827*500*125
5 |
Â
827*500*1255 |
Â
1135*810*1430 |
Â
1450*1110*1880 |
||||||
Package weight(Kg) | 100 | 102 | 105 | 125 | 145 | 215 | 420 | 750 | 860 |
Â
MODEL | T120K | T150K | T200K | T250K | |
Power | 120KW | 150KW | 200KW | 250KW | |
Power Factor | 0.8 | ||||
Â
 Input |
Phase | 3 phase 4 wire and ground | |||
Voltage Range | 380V± 20%(3 phase), phase voltage 220V | ||||
Frequency Range | 45 – 65Hz | ||||
Rectifier | 3 phase 6 pulses, 12 pulses is optional | ||||
Â
  Output |
Phase | 3 phase 4 wire and ground | |||
Wave form | Pure sine wave | ||||
Crest Factor | 3: 01 | ||||
Rated voltage | 380/400/415V      optiona+     -1%   for   static                        load,         5%
forfluctuant load |
||||
Phase voltage setting | 200 – 244VAC, pls confirm when order | ||||
Transient response | +/-5%, 10ms | ||||
Frequency | 50 / 60 Hz + / – 0.05% | ||||
Total-harmonic distorti
on |
< 3% linear load, < 5%( nonlinear load) | ||||
Short circuit current | Short current for 0.1s (200% current) | ||||
Overload capacity | Overload 125% for 10 Mins, 125%-150% for 1min.
automatically resume when load become normal |
||||
Type | Static state + manual maintenance bypass |
Â
Bypass | Input Phase | 3 phase 4 wire and ground | ||||
Input voltage range | 15% – 25% (the front control panel selectable) | |||||
Transfer time | 15% – 25% (the front control panel selectable) | |||||
Â
Battery |
Battery | Maintenance free lead-acid cell | ||||
DC Voltage | 384V | |||||
Max Charge Current | 6-30A adjustable | |||||
Efficiency | Whole unit | > 85% | ||||
Inverter | 95 | 95 | 95 | |||
Remote signalling | Dry contact (battery low, battery discharging, bypass/
fault); output 12Vdc/80mA, Optional parts |
|||||
Communication interface | RS232 ( SNMP, modem optional ) | |||||
Running temperature | 0-40 degree Celsius | |||||
Relative Humidity | Less than 95% (without condensing) | |||||
Noise at 1 M | less than 60 dB | |||||
Degree of protection | IP20 | |||||
Applicable Standards | EN50091-1-EMC EN50091-2liv. A | |||||
Product size(mm) | 1200*900*1820 | 1200*900*1820 | 1200*900*1820 | |||
product weight(Kg) | 950 | 1100 | 1500 | |||
Package size(mm) | 1450*1110*188
0 |
1450*1110*188
0 |
1450*1110*1880 | |||
Package weight(Kg) | 1008 | 1130 | 1550 |
Weight | 100 kg |
---|---|