20KW-250KW Hybrid Solar Inverter

$602.88 $575,982.08
Availability: In Stock
Short Description

The OGARTECH T Series and T120K to T250K Models are industrial-grade, high-power Off-Grid Hybrid Solar Inverters. These inverters are designed to offer high efficiency and flexibility, ideal for large

Available Options

Features:

  • Pure sine wave output
  • With MPPT solar charge controller 30A-100A (Optional) With UPS automatic switching function, grid power charging function, AVR voltage stabilization function
  • It has perfect protection functions such as overload, high voltage, low voltage, short circuit, etc
  • DSP Intelligent Chip Control, Excellent Performance
  • Strong inverting capability, one-time soft start, triple output peak power, with all inductive loads
  • Full personalized LCD display, it can display various data information of inverter, solar charge controller
  • Grid power priority, energy saving mode and solar energy priority can be set freely to meet different occasions
  • Battery type, charging voltage grid power charging current (0- 35A) can be set freely to meet the charging management of different types of batteries

Specification:

 

MODEL T5K T6K T8K T10K T20K T30K T50K T60K T100K
Power 5KW 6KW 8KW 10KW 20KW 30KW 50KW 60KW 100KW
Power Factor 0.8
 

 

 

Input

Phase 3 phase 4 wire and ground
Voltage Range 380V± 20%(3 phase), phase voltage 220V
Frequency Range  

 

45 – 65Hz

Rectifier 3 phase 6 pulses, 12 pulses is optional
 

 

 

 

 

 

 

 

 

Output

Phase 3 phase 4 wire and ground
Wave form Pure sine wave
Crest Factor 3: 01
Rated voltage 380/400/415V optional+ -1% for static load, 5% forfluctuant load
Phase voltage setting  

 

200 – 244VAC, pls confirm when order

Transient response  

 

+/-5%, 10ms

Frequency 50 / 60 Hz + / – 0.05%
Total-harmonic distortion  

 

< 3% linear load, < 5%( nonlinear load)

Short circuit current  

 

Short current for 0.1s (200% current)

Overload capacity Overload 125% for 10 Mins, 125%-150% for 1min. automatically resume when load become normal
 

 

 

Battery

Battery Maintenance free lead-acid cell
DC Voltage 48v or 96V(1-15KW) 384V
Max Charge Current  

 

6-30A adjustable

 

 

 

 

Bypass

Type Static state + manual maintenance bypass
Input Phase 3 phase 4 wire and ground
Input voltage range  

 

15% – 25% (the front control panel selectable)

 

 

Transfer time

Inverter / bypass transfer switch time(Overload): 0ms inverter / bypass transfer switch time (fault inverter) 1ms

 

 

Efficien cy Whole unit > 85%
Inverter 91 91 92 92 93 93 95 95 95
 

 

Remote signaling

Dry contact (battery low, battery discharging, bypass/ fault); output 12Vdc/80mA, Optional parts
Communication interface RS232 ( SNMP, modem optional )
Running temperature 0-40 degree Celsius
Relative Humidity Less than 95% (without condensing)
Noise at 1 M less than 60 dB
Degree of protection IP20
Applicable Standards EN50091-1-EMC EN50091-2liv. A
Product size(mm) 700*364*969 700*364*969 785*580*1200 1200*900*1820
product weight(Kg) 80 82 85 108 125 190 380 690 800
 

 

Package size(mm)

827*500*125

 

5

 

 

827*500*1255

 

 

1135*810*1430

 

 

1450*1110*1880

Package weight(Kg) 100 102 105 125 145 215 420 750 860

 

MODEL T120K T150K T200K T250K
Power 120KW 150KW 200KW 250KW
Power Factor 0.8
 

 

 

Input

Phase 3 phase 4 wire and ground
Voltage Range 380V± 20%(3 phase), phase voltage 220V
Frequency Range 45 – 65Hz
Rectifier 3 phase 6 pulses, 12 pulses is optional
 

 

 

 

Output

Phase 3 phase 4 wire and ground
Wave form Pure sine wave
Crest Factor 3: 01
Rated voltage 380/400/415V       optiona+      -1%    for    static                         load,          5%

 

forfluctuant load

Phase voltage setting 200 – 244VAC, pls confirm when order
Transient response +/-5%, 10ms
Frequency 50 / 60 Hz + / – 0.05%
Total-harmonic distorti

 

on

< 3% linear load, < 5%( nonlinear load)
Short circuit current Short current for 0.1s (200% current)
Overload capacity Overload 125% for 10 Mins, 125%-150% for 1min.

 

automatically resume when load become normal

  Type Static state + manual maintenance bypass

 

 

Bypass Input Phase 3 phase 4 wire and ground
Input voltage range 15% – 25% (the front control panel selectable)
Transfer time 15% – 25% (the front control panel selectable)
 

 

Battery

Battery Maintenance free lead-acid cell
DC Voltage 384V
Max Charge Current 6-30A adjustable
Efficiency Whole unit > 85%
Inverter 95 95 95
Remote signalling Dry contact (battery low, battery discharging, bypass/

 

fault); output 12Vdc/80mA, Optional parts

Communication interface RS232 ( SNMP, modem optional )
Running temperature 0-40 degree Celsius
Relative Humidity Less than 95% (without condensing)
Noise at 1 M less than 60 dB
Degree of protection IP20
Applicable Standards EN50091-1-EMC EN50091-2liv. A
Product size(mm) 1200*900*1820 1200*900*1820 1200*900*1820
product weight(Kg) 950 1100 1500
Package size(mm) 1450*1110*188

 

0

1450*1110*188

 

0

1450*1110*1880
Package weight(Kg) 1008 1130 1550